Characteristics
- CAT. II 700 V / CAT. III 600V
- 24 levels
- DMM with automatic polarity indication and 3 ½-digit LCD display
- Measurements: DC current up to 15 A, AC and DC voltage up to 700 V, resistance up to 20 megohm
- Temperature, diode, battery and continuity test with audible indicator
- Low battery indicator, overcharge protection and automatic shutdown
- With protective case
- With separate test leads (incl.): TLM72
- Capacitance: precision
- Inductance: precision
- Frequency: basic accuracy
- Overload protection:-
- Temperature: -50-150 / 150-800 °C
- Basic accuracy: ± 3°C ± 1 digits for -50°C~150°C range / ± 3% of reading ± 1 digits for 150°C~800°C range
- Overload protection: 0.5 A / 1000 V fuse
- Battery Test: 1.5V / 9V
- Basic accuracy: ± (5.0 % reading + 5 digits)
- Overload protection: 0.5 A / 600 V fuse
- Overload protection: 0.5 A / 1000 V fuse
- Audible continuous measurement: a beep sounds if the resistance is less than 50 Ohm
- Test voltage: ± 3V
- Diode measurement: test diode voltage
- Test voltage: ± 3V
- Overload: yes
- Audible continuity indicator: yes
- Transistor test: yes
- Diode test: yes
- Low battery indicator: yes
- Full screen: 1999
- LCD display size: 61 x 26mm
- Available modes: manual
- Data retention: yes
- Backlight: no
- Dimensions: 165 x 85 x 37 mm
- Weight (with batteries): 215g
- Power supply: 1 9V 6LR61 battery (incl.)
- Packing: blister
- Accessories: manual / probes / case
- Automatic deactivation: yes
- Lead test probe (incl.): CAT III 1000V / CAT IV 600, 15 A, L = 75 cm
Other information
- DC voltage: 200 m / 2 / 20 / 200 / 700 V
- basic accuracy: ± 0.5% of reading ± 2 digits for 200 mV - 200 V range / ± 0.8% of reading ± 2 digits for 700 V range
- input impedance: 10 Mohm
- max input: 700V
- Overload protection: 700V DC or AC rms
- AC voltage: 2 / 20 / 200 / 700 V
- basic accuracy: ± 0.8% of reading ± 3 digits for 2V - 200V range / ± 1.2% of reading ± 3 digits for 700V range
- input impedance: 10 Mohm
- frequency range: 40-500 Hz
- max input: 700V
- DC current: 2m / 20m / 200m / 15A
- basic accuracy: ± 1.2% of reading ± 2 digits for 2 m - 20 mA range / ± 1.5% of reading ± 2 digits for 200 mA range / ± 2.0% of reading ± 3 digits for 15 A range
- overload protection: 0.5 A / 1000 V fuse on mA range, 15 A / 1000 V fuse on 15 A range
- AC Current: 2m / 20m / 200m / 15A
- basic accuracy: ± 1.5% of reading ± 3 digits for 2 m - 20 mA range / ± 2.0% of reading ± 3 digits for 200 mA range / ± 2.5% of reading ± 5 digits for 15 A range
- overload protection: 0.5 A / 1000 V fuse on mA range, 15 A / 1000 V fuse on 15 A range
- frequency range: 40-500 Hz
- Resistance: 200 / 2k / 20k / 200k / 2M / 20M Ohm
- basic accuracy: ± 1.0% of reading ± 3 digits for 200 Ohm range / ± 1.0% of reading ± 2 digits for 2 kOhm~200 kOhm range / ± 1.5% of reading ± 3 digits for 20 MOhm range
- Overload protection: 700V DC or AC rms